Australian  Government 


Department  of  Defence 

Defence  Science  and 
Technology  Organisation 


End  of  Service  Life  Indicator  (ESLI)  for  Respirator 
Cartridges.  Part  I:  Literature  Review 

George  Favas 

Human  Protection  &  Performance  Division 
Defence  Science  and  Technology  Organisation 

DSTO-TN-0657 

ABSTRACT 

One  of  the  critical  elements  related  to  efficiency  and  safe  use  of  respirator  filter 
cartridges  is  their  operational  life  span.  Predicting  the  life  span  of  a  respirator  cartridge 
is  difficult  because  it  is  dependant  on  parameters  such  as  environmental  temperature, 
the  nature  and  concentration  of  the  contaminants  and  the  rate  of  breathing.  Ideally, 
respirator  cartridges  should  include  an  End  of  Service  Life  Indicator  (ESLI)  system  to 
warn  the  wearer  when  it  is  time  to  change  cartridges. 

The  development  of  a  cheap,  reliable,  disposable  ESLI  would  significantly  improve  the 
protection  of  military  units  in  a  chemical  warfare  (CW)  environment.  Currently,  no 
ESLI  is  available  on  the  market  that  is  capable  of  detecting  a  range  of  CW  agents  and 
toxic  industrial  chemicals  (TICs)  and  therefore,  the  commercialisation  potential  of  a 
successful  ESLI  is  high.  This  report  reviews  all  prior  art  relating  to  ESLIs  for  respirator 
cartridges  which  will  provide  the  foundation  for  future  development  in  this  area. 


RELEASE  LIMITATION 


Approved  for  public  release 


Published  by 

Human  Protection  &  Performance  Division 
DSTO  Defence  Science  and  Technology  Organisation 
506  Lorimer  St 

Fishermans  Bend,  Victoria  3207  Australia 

Telephone:  (03)  9626  7000 
Fax:  (03)  9626  7999 

©  Commonwealth  of  Australia  2005 

AR-013-478 

July  2005 


APPROVED  FOR  PUBLIC  RELEASE 


End  of  Service  Life  Indicator  (ESLI)  for 
Respirator  Cartridges.  Part  I:  Literature  Review 

Executive  Summary 

One  of  the  critical  elements  related  to  efficiency  and  safe  use  of  respirator  filter 
cartridges  is  their  operational  life  span.  Predicting  the  life  span  of  a  filter  cartridge  is 
difficult  because  it  is  dependent  on  parameters  such  as  environmental  temperature, 
relative  humidity,  the  nature  and  concentration  of  the  contaminants  and  the  rate  of  air 
passing  through  the  filter.  In  many  cases  the  first  indication  that  the  filter  cartridge  has 
reached  saturation  is  the  odour  of  the  pollutant.  Unfortunately,  this  type  of  practise  is 
very  dangerous  because  the  odour  thresholds  of  many  pollutants  are  above  the 
acceptable  exposure  limits.  Ideally,  respirator  filter  cartridges  should  include  an  End  of 
Service  Life  Indicator  (ESLI)  system  to  warn  when  it  is  time  to  change  filters. 

Although,  the  concept  of  an  ESLI  for  respirator  cartridges  is  not  new,  no  ESLI  is 
available  on  the  market  that  is  capable  of  detecting  both  chemical  warfare  (CW)  agents 
and  toxic  industrial  chemicals  (TICs).  The  integration  of  a  cheap,  reliable,  disposable 
micro-chemical  sensor  would  significantly  improve  ADF  protection  in  a  CW 
environment  by  warning  the  user  when  the  effectiveness  of  their  respirator  cartridge  is 
about  to  expire.  Furthermore,  this  ESLI  technology  could  be  transferred  to  civilian 
respirator  units  and  to  other  ADF  Platform  equipment  such  as  NBC  protective 
ensembles,  air  monitoring  equipment  and  all  other  filtering  systems.  Subsequently,  the 
commercialisation  potential  of  a  successful  ESLI  is  very  high. 

A  comprehensive  literature  review  on  the  history  of  respirator  cartridges  containing 
an  ESLI  is  provided  in  this  report.  This  information  will  provide  the  foundation  for 
future  development  in  the  art  of  ESLI  system. 


Authors 


George  Favas 

Human  Protection  &  Performance  Division 

George  Favas  graduated  from  Monash  University  with  a  B.Sc 
(Hons)  in  1995,  and  with  a  PhD  degree  (Science)  in  2000.  He  is 
also  about  to  submit  a  M.  Eng  Sc  thesis  and  has  concurrently 
almost  completed  a  M.  Bus  Sys  at  the  same  University.  He  worked 
as  a  Post-doctoral  Research  Fellow  in  Chemistry  (2000  -  2002) 
and  in  Chemical  Engineering  (2002  -  2003)  at  Monash 
University.  For  more  than  nine  years,  George  managed  a  number 
of  innovative  scientific  and  engineering  projects  for  the  power 
generators  in  the  Latrobe  Valley,  Flinders  Power  (South 
Australia),  within  several  CRCs,  and  for  a  number  of  national  and 
international  mining  companies  including  Alcoa,  BHP,  Shell 
Australia,  Rio  Tinto  and  NEDO  (Japan).  Furthermore,  he  has 
collaborated  in  research  in  the  US,  Japan,  Indonesia  and  Germany 
and  has  presented  lectures  at  some  of  the  world's  most  prestigious 
universities.  In  September  2003,  George  joined  Defence  Science 
and  Technology  Organisation  (DSTO)  where  he  continued  to  work 
on  carbon  products  and  on  developing  chemical  micro-sensory 
devices. 


Contents 


1.  INTRODUCTION . 1 

2.  LITERATURE  REVIEW . 2 

2.1  Passive  End  of  Service  Life  Indicators . 2 

2.2  Commercially  available  passive  colourimetric  ESLI  respirator  cartridges....  9 

2.3  Non  colourimetric  passive  indicators . 10 

2.4  Active  End  of  Service  Life  Indicators  (AESLI) . 11 

2.5  Current  research  on  ESLIs . 24 

2.6  ESLIs  for  carbon  adsorption  beds . 27 

2.7  Conclusions . 28 

3.  REFERENCES . 29 

APPENDIX  A:  DOCUMENTED  RESPIRATOR  ESLI  MEDIUMS . 39 


DSTO-TN-06 57 


1.  Introduction 


Respirators  using  replaceable  filter  cartridges  are  commonly  used  for  protection 
against  a  wide  range  of  respiratory  hazardous  materials  which  include  toxic  and/or 
disease  producing  dusts,  mists,  sprays,  fumes,  vapours  or  gases.  While  these  devices 
provide  excellent  protection  against  hazardous  materials,  their  protection  capabilities 
diminish  with  use  and  eventually  permit  the  passage  of  the  hazardous  agents  unless 
the  filter  cartridge  is  replaced. 

One  of  the  critical  elements  related  to  efficiency  and  safe  use  of  these  cartridges  is  their 
operational  life  span.  Predicting  the  life  span  of  a  respirator  filter  cartridge  is  difficult 
because  it  is  dependant  on  parameters  such  as  environmental  temperature  \1~3\  relative 
humidity  t444],  the  nature  and  concentration  of  the  contaminants  t15-26]  and  the  rate  of 
breathing  I26-31].  In  many  cases  the  first  indication  that  the  cartridge  has  reached 
saturation  is  the  odour,  taste  or  irritation  from  the  pollutant  t32-34].  Unfortunately,  this 
practise  is  highly  dangerous  because  the  odour  thresholds  of  many  pollutants  are 
above  the  permissible  exposure  limit  t35'  36f  Health  organisations  recommend 
administrating  a  cartridge  change  schedule,  however  these  programmes  can  be  tedious 
and  time  consuming  I37].  Ideally,  respirator  cartridges  should  include  an  End  of  Service 
Life  Indicator  (ESLI)  system  to  warn  the  wearer  when  it  is  time  to  change  cartridges. 

An  ESLI  system  for  respirator  cartridges  can  be  categorised  as  either  passive  or  active 
indicating  systems.  Passive  indicator  systems  typically  include  chemically  coated 
paper  strips,  which  change  colour  when  the  sorbent  material  is  near  depletion.  A  major 
advantage  with  passive  indicators  is  that  they  are  relatively  cheap  to  incorporate  into  a 
respirator  cartridge.  However,  the  major  disadvantages  with  most  passive  indicators 
are  that  they  require  active  monitoring  by  the  user,  observations  can  only  be  conducted 
with  sufficient  lighting  and  the  indicators  are  generally  only  specific  towards  a 
particular  chemical  functional  group. 

In  contrast,  active  indicator  systems  incorporate  electronic  sensors  to  monitor  the 
presence  of  contaminants  and  an  indicator  (either  visual  or  audible  signal)  to  provide 
an  automatic  warning  to  the  user.  Most  active  indicator  systems  have  the  advantage  of 
being  less  selective  towards  specific  chemicals  and  therefore  can  be  used  in  a  range  of 
different  environments,  however  a  major  limitation  to  these  systems  is  the  cost  to 
manufacture. 

A  comprehensive  literature  review  on  the  history  of  respirator  cartridges  containing 
ESLIs  is  provided  in  this  report.  This  information  will  provide  the  foundation  for 
future  development  in  the  art  of  ESLIs  for  respirator  cartridges. 


1 


DSTO-TN-0657 


2.  Literature  review 

2.1  Passive  End  of  Service  Life  Indicators 

End  of  Service  Life  Indicators  (ESLIs)  on  respirators  is  not  a  new  concept.  After  World 
War  I,  Yablick  t38'  39J  patented  a  canister  with  a  built  in  colour  indicating  system  for 
measuring  the  residual  life  of  the  canister  (Figure  1).  Yablick  proposed  that  indicator 
paper  or  solution  specific  to  the  " poisonous  or  obnoxious  gas"  t38'  393  could  be 
incorporated  onto  the  side  of  the  canister. 


Figure  1:  Indicating  gas-mask  canister  (Yablick  W,  1925) 

Dragerwerk  in  1957  I4°]  took  out  a  German  patent  on  a  colourimetric  indicator  located 
in  the  line  of  sight  of  the  user,  inside  the  interior  space  of  the  mask.  The  drawback  to 
this  design  was  that  it  only  warned  the  user  when  a  significant  concentration  of 
harmful  agents  had  already  entered  inside  the  facemask. 


2 


DSTO-TN-06 57 


Figure  2:  Dragerwerk's  patent  with  the  indicator  located  inside  the  face  mask 


In  I960,  Wiswesser  t41]  invented  a  window  indicator  assembly  for  gas  mask  canisters 
for  detecting  moisture  or  vapours.  The  unique  design  of  the  canister's  window  were 
the  two  half  discs  which  made  up  the  indicator.  One  half  of  the  disc  was  permanent  in 
colour  while  the  other  half  contained  the  indicator  paper.  When  both  colours  matched, 
the  service  life  of  the  canister  was  spent.  A  similar  ESLI  principle  is  currently  being 
used  by  North  Safety  Products  (see  Section  2.2). 


A 


B 


Figure  3:  The  Wiswesser  canister ,  1960  W,  (A)  canister  with  window  indicator  assembly 
(B)  two  half  discs  making  up  part  of  the  ESLI. 


Similarly,  Roberts  t42]  in  1976  designed  a  colourimetric  indicator  for  detecting  the  end  of 
service  life  of  a  canister  for  filtering  vinyl  organo  materials  (Figure  4).  The  devices  of 
Yablick  t39],  Wiswesser  t41]  and  Roberts  t42]  used  indicators  supported  by  thin  opaque 
carriers  such  as  strips  of  paper,  activated  alumina  or  the  cartridge  sorbent  itself  so  that 
only  a  portion  of  the  indicator  against  the  window  was  visible.  Similarly,  Wing's 


3 


DSTO-TN-0657 


respirator  patent  in  1982  also  included  an  indicator  strip,  located  horizontally  across 
the  canister  I43]. 


Figure  4:  Colourimetric  vinyl  chloride  indicator  (Roberts  t42(  1976) 

In  1978,  Auergesellschaft  GMBH  patented  I44l  a  supplementary  filter  attachment  for 
increasing  the  operational  efficiency,  effectiveness  and  hence  the  service  life  of 
respirator  cartridges  (Figure  5).  This  supplementary  attachment  contained  a  drying 
agent  in  front  of  the  filter  bed  and  a  colourimetric  window  for  indicating  when  this 
drying  agent  was  spent.  This  patent  claimed  to  increase  the  residual  life  of  the  catalyst 
contained  inside  the  respirator  cartridge  however  the  major  drawback  to  this  design 
was  that  it  did  not  notify  the  user  when  the  main  respirator  itself  was  completely 
spent. 


Figure  5:  Auergesellschaft  GMBH's  supplementary  filter  attachment  containing  a  drying 
agent  and  colourimetric  indicator  lul 


4 


DSTO-TN-06 57 


In  1979,  McAllister  et.  al  t45]  patented  an  ESLI  on  a  filter  mask  for  vinyl  chloride 
monomers.  This  patent  was  similar  to  the  Roberts  patent  t42]  however  the  major 
difference  was  the  addition  of  manganese  (IV)  oxide  (MnCh)  to  the  potassium 
permanganate  (KMnCh)  indicator  in  the  McAllister  et.  al  patent  t45l.  The  presence  of 
MnCh  with  KMnCh  was  claimed  to  give  a  better  colour  contrast  from  start  to  finish 
thereby  making  the  indicator  much  easier  to  read. 


The  American  Optical  Corporation  in  1979  took  out  several  patents  for  cartridge  ESLIs. 
Their  first  invention  t46'  47]  was  similar  to  Yablick  t39]  however  its  specific  use  was  for 
both  water-soluble  and  water-insoluble  organic  vapours.  In  this  patent,  sodium  or 
potassium  dichromate  (K^C^Oz)  gave  a  colour  change  in  the  presence  of  aromatics, 
chlorinated  compounds  and  aliphatic  ketones.  The  visual  indication  that  the  cartridge 
service  life  had  ended  was  designed  to  occur  before  the  threshold  limit  value  (TLV) 
had  been  exceeded  (Figure  6).  Unfortunately,  a  major  problem  with  this  design  was  the 
shelf  life  of  the  ESLI  was  considerably  shorter  than  the  cartridge  sorbent  t48]. 
Tanaka  et.  al  W  reported  that  2  years  after  manufacture,  the  indicator  changed  colour 
despite  the  cartridge  not  being  worn,  consequently  these  cartridges  were  not  approved 
in  Japan  t49]. 


Figure  6:  ESLI  for  organic  vapours  (American  Optical  Corporation  1979) 

In  1985,  the  American  Optical  Corporation  updated  their  patent  to  include  a  sieve 
material  to  the  indicator,  whose  sole  function  was  to  selectively  adsorb  water  t5°].  The 
dried  chemical  agents  were  found  to  give  faster  response  times,  better  resolution  in  the 
colour  change  on  the  ESLI  and  a  significant  improvement  on  the  shelf  life  of  the 
indicator. 


Figure  7:  The  addition  of  a  drying  compartment  before  the  indicator  improved  sensitivity 
towards  the  end  of  service  life  of  the  cartridge  (American  Optical  Corporation  t5°],  1985) 


5 


DSTO-TN-0657 


Eian  in  1981  t5k  52]  used  a  colourimetric  indicator  sheet  positioned  along  the  inner 
transparent  sidewall  of  the  respirator  cartridge  (Figure  8).  The  novelty  of  this  invention 
was  the  transparent  sidewall,  which  allowed  the  indicator  to  show  the  remaining 
capacity  of  the  entire  sorbent  bed  rather  than  the  condition  of  a  small  volume  near  the 
indicating  window. 


Figure  8:  Respirator  design  of  Eian  t52l  with  built  in  indicator  sheet. 


In  1984,  TNO  patented  t53]  a  gas  mask  module  for  detecting  poisonous 
organophosphates  (eg  insecticides,  nerve  agents  etc)  using  an  enzyme  (butyryl 
cholesterinase).  The  method  of  operation  involved  attaching  the  module  at  the  end  of  a 
gas  mask  and  after  a  certain  suction  time  had  elapsed,  the  module  was  detached  and  a 
second  liquid  reagent  was  released  from  inside  the  module.  The  non-decolourisation  of 
the  second  reagent  was  an  indicator  that  the  threshold  concentration  had  been 
exceeded.  The  obvious  drawbacks  to  their  module  design  include  the  lack  of  a  real 
time,  passive  monitoring;  the  cost  of  replacing  a  new  module  with  every  subsequent 
test;  and  the  annoyance  of  being  forced  to  remove  the  module  from  the  mask  in  order 
to  conduct  a  threshold  level  test. 

In  1986,  Dragerwerk  t54'  55]  patented  a  respirator  cartridge  design  equipped  with  a 
colourimetric  indicator  (Figure  9).  The  uniqueness  of  this  design  was  the  small 
chamber  located  between  the  adsorbent  bed  and  the  upper  void  space,  which 
contained  the  indicator.  A  magnifying  glass  positioned  on  the  external  wall  of  the 
cartridge  assisted  viewing  colour  changes  in  the  indicator  and  the  progression  of  air 
through  the  flow  indicator.  Furthermore,  this  patent  postulated  that  several  of  these 
chambers  could  be  immersed  at  different  depths  inside  the  adsorbent  bed  for 
providing  a  chronological  progression  of  hazardous  vapours  through  the  cartridge. 


6 


DSTO-TN-06 57 


In  1994,  Draegerwerk  t56]  improved  the  detection  device  from  their  1957  patent  t4°]  by 
designing  a  system  that  prevented  toxic  gases  from  reaching  the  indicator  strip  before 
the  face  mask  was  worn  and  allowed  the  activation  of  the  indicator  strip  while  wearing 
the  face  mask.  However,  similar  to  their  1957  patent,  the  design  does  not  provide 
adequate  warning  because  the  colourimetric  change  only  occurs  when  toxic  gases  have 
already  entered  the  facemask. 


Figure  10:  Draegerwerk's  breathing  mask  with  an  indicator  signalling  penetration  of  a  toxic 
substance  into  the  mask  t56l 


7 


DSTO-TN-0657 


In  1995,  Haddington  Is7 1  took  out  a  World  patent  on  a  respiratory  filter  indicator 
(Figure  11).  The  unique  aspect  of  Haddington's  design  was  the  positioning  of  the 
indicator  (composed  of  an  activated  alumina  which  had  been  impregnated  with  an 
indicator  (eg  potassium  permanganate))  in  between  the  facemask  and  respirator 
cartridge. 


Figure  22:  Indicator  module  attached  to  a  filter  cartridge  and  mask  f57i 


In  2002,  North  Safety  Products  took  out  several  patents  on  a  "respirator  cartridge  with 
service  life  indicator"  I58'  591  Similar  to  Yablick's  design  in  1925  I38!,  the  North  Safety 
Products  patent  used  a  strip  of  indicator  paper  to  detect  the  presence  of  acidic  agents. 
The  major  difference  to  the  North  Safety  Products'  invention  was  the  cartridge's 
mechanistic  design,  which  allowed  the  wearer  to  continuously  rotate  the  cartridge  in 
the  one  direction  until  the  colour  changing  display  was  in  the  line  of  sight. 


A  B 

Figure  12:  The  ESLI  system  patented  by  North  Safety  products  (A)  cartridge  and  position  of 
the  paper  indicator  (B)  colour  changes  associated  with  particular  acidic  agents  t58l 

Recently  in  2003  and  2004,  Scentczar  Corp  (US)  t60'  patented  a  simple,  low-cost, 
residual  life  indicator  badge  for  measuring  the  remaining  life  of  adsorbent  beds 
towards  volatile  organic  compounds.  Their  design  involved  a  concentric  pattern 
containing  a  colourimetric  indicator  that  was  indexed  to  match  the  residual  life  of  an 
adsorbent  bed.  Scentczar  Corp  claimed  that  this  badge  could  also  be  applied  to 


8 


DSTO-TN-06 57 


respirator  cartridges,  however  a  major  problem  to  this  claim  is  that  the  residual  life  on 
the  indicator  badge  may  not  adequately  match  the  remaining  life  of  their  respirator 
cartridge.  That  is,  the  rate  of  breathing  by  different  people,  in  particularly  during 
different  periods  of  activity,  will  not  be  the  same. 


Quiet  pattern - *■ 

H 

Indicalor  dye  spo!— 

circle - -  M 

Outer  panem— 


-fflslcnej 


.support 


A 


B 


Figure  13:  Scentczar  Cory'S  residual  life  indicator  (A)  front  view  (B)  side  view 

While  these  patents  provide  important  historic  advancements  in  the  art  of  ESLIs,  there 
still  remains  a  need  for  greater  sensitivity  to  cartridge  sorbent  exhaustion  and  the 
ability  to  be  used  in  a  range  of  toxic  environments. 


2.2  Commercially  available  passive  colourimetric  ESLI  respirator 
cartridges 

In  1998,  the  Occupational  Safety  and  Health  Administration  (OSH A)  recommended 
that  employers  provide  respirators  equipped  with  a  National  Institute  for  Occupational 
Safety  and  Health  (NIOSH)  certified  ESLI  for  the  expected  contaminant  or  to 
implement  a  cartridge  change  schedule  to  ensure  that  the  cartridges  are  replaced 
before  contaminant  breakthrough  occurred  I62]. 


In  February  2002,  many  respirators  containing  passive  ESLI  were  withdrawn  from  the 
market  because  the  indicator  on  the  cartridge  was  not  visible  while  wearing  the  full 
face  piece  t63]. 


Currently,  North  Safety  Products  is  the  only  company  offering  more  than  one 
respirator  cartridge  containing  an  ESLI.  Currently  four  respirator  cartridge  types 
suitable  for  organic  vapours,  acidic  (i.e.  HC1,  HF,  SO2,  H2S),  basic  (i.e.  ammonia) 
and/or  mercury/ chlorine  environments  are  being  sold  (Table  1).  The  design  of  the 
respirator  cartridges  is  very  similar  to  their  patents  (see  passive  indicator  systems; 
Section  2.1)  which  allows  the  cartridge  to  be  continually  rotated  in  the  one  direction 
until  the  indicator  is  visible  from  the  face  piece. 


9 


DSTO-TN-0657 


Table  1:  Commercial  respirators  with  built  in  ESLIs  by  North  Safety  Products  t64l 


Respirator 


Description 


Organic  vapour  (Toluene  Diisocyanate) 


HC1,  HF,  S02,  H2S 


Ammonia 


Mercury,  chlorine 


One  of  the  major  drawbacks  to  the  North  Safety  ESLI  design  is  its  limitation  to  detect 
only  a  few  selected  chemical  functional  groups.  Consequently,  this  respirator  ESLI 
would  not  be  adequate  when  multiple  hazardous  chemicals  with  different  functional 
groups  are  present  t65! 

2.3  Non  colourimetric  passive  indicators 

A  unique  ESLI  concept  suggested  by  Wollin  et.  al  t66]  in  1932  for  indicating  the 
exhaustion  of  filters  was  to  use  a  substance,  which,  when  exposed  to  an  air  impurity, 
would  release  a  chemical  that  a  user  could  detect  by  its  taste  or  smell.  In  this  patent,  the 
example  of  hydrocyanic  gas  penetrating  through  a  filter  bed  could  be  detected  by 
using  nicotine  to  produce  a  characteristic  odour,  which  would  subsequently  notify  the 
user  to  change  filter. 

Similarly,  Wing  t43]  in  his  1982  canister  patent  also  suggested  that  the  release  of 
stimulant  as  a  warning  device  for  canister  expiration  however,  details  of  the  chemicals 
involved  in  this  process  were  not  disclosed  in  the  patent. 

In  1998  TNO  t67]  further  developed  this  concept  and  patented  an  odourant,  to  notify  the 
user  (by  smell)  that  the  respirator  cartridge  was  about  the  expire  (Figure  14).  The 
patent  claimed  that  when  organic  vapours  and  dangerous  substances  are  adsorbed  into 
the  respirator  and  come  into  contact  with  the  odour  impregnated  active  carbon,  the 
odorant  becomes  displaced  from  the  carbon  and  is  passed  along  with  the  air  to  the 
user  [67-69]  The  user  recognises  the  smell  as  an  indicator  thus  signifying  the  respirator  is 
about  to  lose  its  effectiveness. 


10 


DSTO-TN-0657 


Canister 


of  adsorbent 

gg|  R-1  CARBON 

substrate  loaded  with  odourant 


1  ELC  CARBON  LOADED 
WITH  ]  SO  AMYL  ACETATE 
(0,2827g!AA/gELC  CARBON) 


Influent 


A 


Effluent 

air 

- Noaeldetector 


f\  Carbon 

|  Loaded  adsorbent 


B 


Figure  14:  Side  view  of  the  respirator  cartridge  (A)  patents  t67'  681  (B)  Linders  t7°] 


Despite  this  indicator  concept  being  unique  to  the  art  of  respirator  ESLI,  there  still 
remains  doubt  on  the  user's  adequate  timely  disposal  of  the  respirator  cartridges. 
Human  factors  such  as  individual  olfactory  sensitivity  under  different  breathing  rates 
and  under  different  health  conditions  (eg  nasal  passages  blocked  because  of  a  cold), 
individual  placebo  effects  and  diminished  olfactory  sensitivity  towards  repeated 
exposure  to  the  odorant,  could  result  in  early  or  late  disposal  of  the  respirator 
cartridges.  Early  disposal  of  respirator  cartridges  will  in  turn  increase  the  operational 
costs  in  replacing  the  cartridges  whereas,  late  disposal  could  potentially  result  in 
hazardous  inhalation  of  the  agent.  Furthermore,  user  doubts  on  respirator  effectiveness 
may  hinder  user  confidence  and  performance  under  hazardous  conditions. 

2.4  Active  End  of  Service  Life  Indicators  (AESLI) 

AESLI  systems  are  comprised  of  electronic  components  to  monitor  the  level  of 
contaminants  and  a  visual  or  audible  signal  to  provide  an  automated  warning  to  the 
user. 

In  1965,  Loscher  Ei]  developed  a  mechanical-electrical  alarm  device  for  detecting 
organic  vapours  inside  air  purifying  canisters.  In  this  design,  wax  was  applied  to  join 
two  wires  that  supported  a  spring  inside  the  probe.  In  the  presence  of  organic  vapours, 
the  wax  lost  its  strength  and  released  the  spring  to  activate  an  alarm  light.  The  likely 
drawbacks  to  this  design  were  its  complexity  and  its  potential  for  false  alarms  due  to 
changes  in  environmental  temperature. 


11 


DSTO-TN-0657 


A  B 


Figure  15:  Loscher's  mechanical-electrical  ESLI  tm  (A)  the  respirator  canister  (B)  the 
cylindrical  probe. 

In  1973,  Wallace's  first  patent  t72]  measured  the  remaining  capacity  of  an  oxygen- 
producing  canister  by  applying  an  electrode  into  the  canister's  potassium  superoxide 
adsorbent  bed.  Oxygen  producing  canisters  have  been  patented  elsewhere  t73"78] 
however  Wallace's  unique  design  measured  changes  in  electrical  resistance  with 
increasing  water  adsorption  and  an  alarm  was  triggered  when  the  sorbent  material 
was  almost  completely  saturated.  The  major  drawback  to  this  design  was  that  oxygen- 
producing  canisters  have  relatively  short  life  spans  (eg  ~25  min)  whereas  carbon  based 
canisters  can  be  operated  for  much  longer  periods  (dependant  predominantly  on  the 
concentration  of  contaminants  being  filtered). 

In  1975,  Wallace's  second  t79]  patent  was  an  electronically  actuated  safety  alarm  system 
for  detecting  the  presence  of  toxic  gases  (eg  acid,  acid  precursor  and  alkyl  halide) 
(Figure  16)  by  measuring  changes  in  the  electrical  resistance  of  nitrogen  containing 
polymers.  The  presence  of  toxic  gases  was  found  to  convert  the  nitrogen  containing 
polymers  into  quaternary  ammonium  salt  groups,  which  significantly  reduced  the 
electrical  resistance  measured  by  the  electrode.  Furthermore,  the  author  claimed  that 
the  active  indicator  could  be  integrated  into  respirator  cartridges  by  drilling  a  hole  in 
the  cartridge  wall  and  mounting  the  electrode  into  the  activated  carbon  component. 


12 


DSTO-TN-06 57 


Figure  16:  Electronic  alarm  system  for  detecting  hazardous  gases  by  measuring  changes  in  the 
electrical  resistance  of  nitrogen  based  polymers  (A)  respirator  cartridge  (B)  detector  system 


Also  in  1975,  Wallace  was  awarded  his  third  patent  t8°]  on  a  respirator  alarm  system  for 
detecting  the  presence  of  toxic  gases.  In  this  design,  two  electrodes  (at  least  one 
electrode  coated  with  an  electrically  insulating  material  of  low  melting  point  (eg  wax)) 
were  positioned  into  the  carbon  filter  bed  (Figure  17).  The  patent  claims  that  in  the 
presence  of  toxic  gases,  heat  is  generated  in  the  carbon  bed,  which  subsequently  melts 
the  wax  to  complete  an  electrical  circuit  between  the  electrodes  through  the  charcoal. 
The  alarm  is  then  activated  on  completion  of  the  electrical  circuit. 


Figure  17:  Wallace's  thermally  activated  warning  system  for  respirator  canisters  t80l 


13 


DSTO-TN-0657 


In  1978,  NIOSH  selected  a  metal  oxide  gas  sensor  (MOGS)  to  act  as  service  life 
indicator  for  organic  vapour  air  purifying  respirators  The  MOGS  was  chosen  on  the 
basis  of  its  low  cost,  commercial  availability  and  its  desirable  non-specificity  to  a  large 
number  of  organic  vapours.  The  drawback  to  the  MOGS  was  the  large  current  drain 
caused  by  the  relatively  high  operational  temperature  (~200°C). 


Detector  installed  on 
one  cartridge  of  respirator 


Battery  pack 


Figure  18:  NIOSH' s  prototype  ESLI  containing  a  metal  oxide  gas  sensor  on  one  side  of  the 
respirator  cartridge. 


In  1979,  the  American  Optical  Corporation  patented  t82]  an  exothermic  sensor  located  in 
the  cartridge  adapter  or  in  the  facemask  cavity  (Figure  19).  The  backbone  to  this 
invention  (similar  to  Wallace's  thermally  activated  warning  system  t8°])  was  the  heat 
released  when  a  gas  becomes  adsorbed  onto  the  surface  of  the  activated  charcoal.  This 
sensor  subsequently  monitored  the  heat  evolved  during  adsorption  of  the  gas  into  the 
adsorbent.  The  patent  reported  a  significant  amount  of  heat  can  be  generated,  typically 
10°  -  15°C  for  organo-chloride  agents  adsorbing  onto  activated  charcoal.  The  invention 
design  also  incorporated  a  reference  element  to  cancel  out  signals  caused  by  ambient 
temperature  fluctuations  thus  eliminating  false  alarms.  A  major  disadvantage  to  the 
design  was  that  during  periods  of  low  concentration,  prolonged  agent  exposure,  the 
charcoal  adsorbent  became  saturated  and  differential  temperature  changes  could  not 
be  detected  to  trigger  the  alarm. 


14 


DSTO-TN-06 57 


Figure  19:  Electronic  circuit  diagram  for  detecting  the  cartridge's  end  of  service  life  t82l 


In  1984,  NIOSH  recommended  that  AESLIs  should  provide  an  advanced  warning  to 
the  user  when  90  percent  of  the  cartridge  is  expended  t83]. 

In  1989,  Auergesellschaft  GMBH  patented  t84'  85J  a  respirator  cartridge  attachment 
containing  a  warning  device  that  was  capable  of  detecting  dangerous  gases  using 
standard  electrochemical  measuring  cells  (Figure  20).  The  proposed  warning  cartridge 
was  designed  to  fit  in  between  the  facemask  and  respirator  filter  cartridge  (Figure  21). 
The  electrochemical  measuring  cells  continually  measured  the  concentration  of  toxic 
gases  (eg  carbon  monoxide,  chlorine,  hydrogen  sulfide  and  hydrogen  cyanide)  and  an 
alarm  (visual  and  audible)  was  triggered  when  the  level  of  these  toxic  gases  had 
reached  above  a  predetermined  concentration.  A  likely  drawback  to  this  design  is  that 
toxic  gases  could  only  be  detected  once  filter  breakthrough  had  occurred  therefore,  the 
system  may  not  comply  with  NIOSH  recommendations  because  it  does  not  provide 
adequate  warning  for  the  user  to  evacuate  from  the  hazardous  environment  and 
change  cartridges. 


A  B 


Figure  20:  Auergesellschaft  GMBH's  respirator  shaped  warning  device  containing 
electrochemical  sensor  t84-  S5l  (A)  side  view  (B)  top  view. 


15 


DSTO-TN-0657 


Figure  21:  Auergesellschaft  GMBH's  warning  device  positioned  between  face  mask  and 
respirator  cartridge  filter  ^  85l 

In  1989  Stetter  took  out  a  US  patent  ^  and  in  1990  was  awarded  a  German  patent  t87] 
on  a  chemiresistor  sensor  device  for  respirator  cartridges  (Figure  22).  This  indicator 
device  gave  a  real-time  warning  on  the  extent  of  absorbent  saturation  by  measuring  the 
electrical  conductivity  of  a  chemically  reactive  coating.  The  patent  proposed  that  this 
sensor  advantageously  gave  a  generic  response  to  many  contaminants  inside  the  filter 
cartridge  and  that  the  sensor  unit  required  marginal  power  at  room  temperature.  In 
addition,  the  patent  claimed  that  an  electronic  compensated  bridge  circuit  design  could 
minimise  baseline  shifts  from  changes  in  ambient  conditions,  such  as  temperature  and 
relative  humidity. 


A  B 

Figure  22:  Stetter’ s  design  >S7l  (A)  face  mask  and  respirator  cartridge  (B)  respirator  cartridge 
with  chemiresistor  sensor. 


16 


DSTO-TN-06 57 


In  1991,  Stetter  repositioned  the  alarm  from  the  side  of  the  respirator  cartridge 
(Figure  22)  to  the  front  of  the  face  mask  (Figure  23).  This  new  position  did  not  obstruct 
the  user's  vision  and  was  clearly  visible  when  flashing  t88]  (Figure  23).  In  1993,  Stetter's 
group  t89]  reported  that  chemiresistor  sensors  were  suitable  for  detection  of  organic 
vapours  such  as  ethyl  acetate  however  further  improvements  in  the  stability  and 
sensitivity  were  necessary. 


Stetter  later  patented  the  chemical  gas  sensor  for  the  respirator  cartridge  in  1996  t9°].  In 
this  patent  Stetter  claimed  that  changes  in  electrical  impedance  resulting  from  changes 
in  a  vapour  sensitive  polymer  could  be  utilised  to  detect  the  presence  of  organic 
vapours. 


FLASHING  LED 
ALARM 


Figure  23:  Schematic  of  the  prototype  ESLI  mounted  on  a  full  fask  mask  t88l 


In  1991,  Geraetebau  GMBH  t91]  incorporated  several  gas  sensors  (Figure  24)  located 
behind  the  filter  cartridge  on  positive  pressure  gas  masks.  This  indicator  system 
monitored  the  changes  in  gas  electrical  resistance,  voltage  or  capacitance  and  an  alarm 
was  triggered  when  the  levels  were  outside  predetermined  limits.  Unfortunately,  it  is 
unlikely  that  this  system  could  be  incorporated  into  a  stand-alone  negative  pressure 
respirator  unit  (eg  the  S10  respirator  unit)  because  of  its  high-energy  demand,  its  high 
cost  of  manufacture  and  its  cumbersome  size. 


17 


DSTO-TN-0657 


IH^L&9  id#  Stiff! i  conductor 


g]@£irckfa 


tilecttod# 


cteramfc 


lltitil w 


Ell  bod# 


declftilyl# 


GA& 


E 


Figure  24:  The  five  sensors  proposed  by  Geraetebau  GMBH's  positive  pressure  gas  mask  W 

(A)  explosive  sensor  based  on  the  principle  of  "heat  of  reaction"  or  "catalytic  combustion" 

(B)  thermal  conductivity  sensor  (C)  an  electrolytic  "redox  based"  carbon  monoxide  sensor 
(D)  semiconductor  sensor  for  toxic  chemicals  (E)  an  electrolytic  "redox  based"  oxygen 
concentration  sensor 


In  1994  Dragerwerk  \-92\  patented  a  mask  and  respirator  unit  which  controlled  the 
passage  of  inhaled  air  through  an  indicator.  The  indicator  simultaneously  registered 
the  retention  effect  of  the  filter  and  the  sealing  effect  of  the  edge  of  the  mask. 
Furthermore,  this  patent  proposed  the  use  of  a  miniaturized  computer  chip-like 
indicator  system  capable  of  detecting  pollutants  at  different  levels.  The  indicator 
system  itself  was  anticipated  to  consist  of  a  light  source  and  detector.  The  light 
intensity  (measured  in  transmission  or  reflection)  was  a  measure  of  the  amount  of 
pollutant  received  by  the  indicator. 


18 


DSTO-TN-06 57 


Figure  25:  Electronic  indicator  system  using  a  light  source  and  detector  t92l 

The  Minnesota  Mining  and  Manufacturing  Company  (3M  Company)  took  out  a  World 
patent  in  1996  t93]  and  US  patent  in  1997  t94]  on  a  very  sophisticated  respirator  ESLI.  The 
unique  aspect  of  this  invention  was  the  air  sampling  device  attached  to  the  side  of  the 
respirator.  Air  passing  through  the  sorbent  material  was  constantly  sampled  and 
processed  to  give  an  active  indication  (eg  audio,  visual  or  tactile  response)  to  the 
concentration  signal.  The  signalling  rate  of  the  indicator  varied  as  a  function  of  target 
species  concentration. 

The  invention  also  allowed  interchanging  of  exposure  indicators  for  detecting 
alternative  agents  without  interfering  with  the  flow  of  air  through  the  respirator. 
Furthermore,  the  processing  device  was  capable  of  being  removed  from  the  respirator 
to  measure  the  concentration  of  the  target  species  in  the  ambient  air  and  then  replaced 
back  onto  the  respirator  to  measure  the  concentration  of  the  agent  flowing  through  the 
cartridge.  In  addition,  a  range  of  complex  sensors  could  be  attached  to  the  respirator 
unit  for  monitoring  the  concentration  of  hazardous  agents. 

The  only  limitation  to  this  unit  design  was  the  positioning  of  the  indicator  directly 
behind  the  respirator  cartridge,  which  could  be  potentially  dangerous  if  the  cartridges 
were  not  immediately  replaced  after  the  indicator  had  alarmed.  Furthermore,  it  is 
uncertain  whether  this  ESLI  system  satisfies  the  NIOSH  recommendations  t83]  in 
notifying  the  user  when  the  cartridge  had  reached  90%  saturation,  thus  allowing  the 
user  sufficient  time  to  change  cartridge  or  to  evacuate  from  the  hazardous 
environment. 


19 


DSTO-TN-0657 


fkivv  [mill 


UanapararilwQsing^  iudifisljM 

exposure  Ludicunii 


A 


p I YH jj !"! !"1  U I  htilttUlgl 
traiufmenl  homing 


Figure  26:  Air  sampling  ESLI 


[93] 


face  mask 


exposure 


tiller  cartridge 


Figure  27:  Position  of  the  ESLI  relative  to  the  face  mask  and  respirator  cartridges  W 


20 


DSTO-TN-06 57 


Bernard  et.  al [95  96]  took  out  a  European  patent  in  1998  I95],  World  patent  in  1999  [%]  and 
US  patent  in  2002  t97]  on  a  respirator  cartridge  containing  a  relatively  simple  fibre  optic 
chemical  sensor  (FOCS)  for  indicating  the  end  of  service  life  of  the  unit.  The  indicator 
concept  design  appeared  to  be  similar  to  the  Dragerwerk  patent  t92f  That  is,  when  the 
light  intensity  measured  by  the  detector  fell  below  a  predetermined  level,  an  alarm  was 
triggered  signifying  gas/ vapour  saturation  and  the  expiration  of  the  cartridge.  Bernard 
et.  al  t95'  %]  claimed  that  this  approach  for  the  detection  of  hazardous  materials  was 
more  universal  than  any  prior  ESLI  because  the  indicator  was  not  selective  and  worked 
with  all  products  susceptible  of  being  absorbed  by  activated  carbon  and  by  the  porous 
silica  (Figure  28  and  Figure  29).  That  is,  when  the  porous  silica  became  saturated,  the 
light  intensity  passing  to  the  detector  decreased. 


Figure  28:  Fibre  optic  containing  a  microporous  glass  section  (surface  area  ~250m2/g) 


(A) 


Figure  29:  Fibre  optic  chemical  sensor  (FOCS)  for  respirator  cartridge  (A)  FOCS  with  light 
source  and  detector  (B)  electronic  module  connected  to  FOCS ,  (C)  sensor  connected  inside 
respirator  cartridge  t95l 


Furthermore,  the  Bernard  et.  al  patent  t95'  %]  used  relatively  cheap  and  common 
electrical  components  (i.e.  phototransistor  detector,  electrolight  diode  in  the  infrared 
region  (800nm)  and  a  LED  alarm.  The  simplicity  of  this  design,  the  relatively  low  cost 
to  manufacture  and  its  effectiveness  to  detect  a  range  of  hazardous  components  are 
attractive  features  to  the  commercialisation  of  this  respirator  ESLI  design. 


21 


DSTO-TN-0657 


Gordik  t98]  in  2001  was  granted  a  Russian  patent  on  a  gas  mask  and  respirator  design 
for  determining  the  time  of  protective  action  from  mercury  vapours.  The  inventor 
claimed  an  increased  efficiency  and  simplified  construction  design  for  measuring  the 
amounts  of  mercury  aerosol  passing  through  the  filter.  The  drawback  to  this  ESLI 
device  was  that  it  could  not  operate  in  other  toxic  environments. 

In  2001,  the  Health  and  Epidemic  Prevention  Station  in  the  Peoples  Republic  of  China 
patented  a  filter-mask  with  an  expiry  indicator  suitable  for  organic  toxic  gases.  The 
unique  feature  of  this  respirator  design  was  the  electronic  gas  sensory  device,  which 
alarmed  when  the  canister  had  become  saturated  with  the  adsorbed  organic  gas  ["]. 
The  respirator  design  positioned  the  sensor  directly  behind  the  respirator  cartridge 
(similar  to  the  3M  patent  in  1997)  and  an  auditory  alarm  system  positioned  on  the  side 
of  the  cartridge  (Figure  30).  Unfortunately,  the  type  of  sensory  system  for  the  detection 
of  chlorinated  hydrocarbon  vapours  was  not  disclosed  in  the  patent. 


respiratory  valve 


Figure  30:  Filter  mask  with  expiry  indicator  for  organic  gases  t"i 


In  2002,  Shigematsu  et.  al  t100]  also  patented  a  gas  mask  with  the  sensor  positioned 
between  the  respirator  cartridge  and  face  mask  (Figure  31).  This  Japanese  patent 
detected  the  presence  of  organic  gases  electronically  by  monitoring  colourimetric 
changes  of  the  indicator  paper  located  inside  the  cartridge.  Furthermore,  an  LED  light 
connected  from  the  sensor  and  the  warning  device  (Figure  31)  notified  the  wearer 
when  it  was  time  to  change  cartridge.  The  patent  claimed  the  warning  system 
incorporated  in  the  cartridge  met  Japanese  approval  standards. 


22 


DSTO-TN-0657 


Figure  31:  Schematic  of  a  Japanese  respirator  ESLIfor  organic  gases  two 1 

In  2003,  Hori  et.  al  I101!  tested  a  respirator  containing  a  commercially  available 
semiconductor  gas  sensor.  The  device  (Figure  32)  appears  to  be  very  similar  to  the 
Shigematsu  et.  al  I100!  Japanese  patent  (Figure  31).  Hori  et.  al  I101'  1021  reported  that 
breakthrough  of  organic  vapours  could  be  detected  at  various  humidities  however 
early  detection  of  chlorinated  hydrocarbons  (eg  chloroform)  was  less  successful. 
Furthermore,  the  major  drawbacks  to  this  electronic  ESLI  design  include  a  high  power 
consumption  (6V);  a  low  effective  operational  time  (6  to  8  hours);  a  high  running  cost 
(i.e.  replacement  of  batteries);  and  a  cumbersome  size  that  may  restrict  worker 
effectiveness. 


23 


DSTO-TN-0657 


Figure  32:  Hori  et.  al's  respirator  design.  (1)  semiconductor  sensor,  (2)  covering,  (3)  control 
box  with  alarm  system,  (4)  power  switch,  (5)  sensitivity  knob,  (6)  alarm  indicator, 

(7)  earphonet101! 


2.5  Current  research  on  ESLIs 


Several  organisations  are  currently  developing  active  ESLIs  and  are  subsequently  being 
tested  in  defence  institutions  around  the  world. 


Scentcar  Corporation  is  currently  evaluating  an  active  residual  life  indicator  for 
detecting  the  build  up  of  volatile  organic  carbons  (VOCs),  using  a  semiconductor 
sensor  I103!  (Figure  33).  This  semiconductor  sensor  measures  the  concentration  of  the 
contaminant  on  the  carbon  bed  (via  changes  in  electrical  resistance)  and  subsequently 
estimates  its  remaining  capacity.  In  contrast,  the  semiconductor  Active  ESLI  patents  of 
Wallace  in  1975  I7?]  and  Stetter  in  1990  I87l  (see  Section  2.4)  did  not  measure  contaminant 
concentration  but  instead  alarmed  to  the  presence  of  the  contaminant. 


Figure  33:  Scentcar  Corporation's  Active  ESLI  l103! 


The  likely  limitations  of  Scentcar  Corporation's  active  sensor  would  be  portability,  cost 
and  high  power  consumption.  This  active  sensor  is  currently  being  tested  at  the  US 
Naval  Research  Laboratory  (NRL)  l103!. 


24 


DSTO-TN-0657 


Cyrano  Sciences  in  the  US  have  commercialised  a  handheld  "electronic  nose",  called 
the  Cyranose®  which  has  the  capacity  to  discriminate  between  closely  related 
gases/ vapours.  The  backbone  to  Cyrano  Sciences's  electronic  nose  is  an  array  of  32 
carbon  black-organic  polymer  composite  chemiresistor  sensors  t104].  In  the  presence  of  a 
gas/ vapour,  these  sensors  respond  creating  a  pattern  across  the  array,  which  is 
identified  using  pattern  recognition  software  [105f  Similar  chemiresistors  are  currently 
being  investigated  as  ESLIs  and  as  residual  life  indicators  for  respirator  cartridges  and 
for  full  body  protection  gear  t106]  (Figure  34).  The  US  NRL  is  also  currently  evaluating 
Cyrano  Sciences's  chemiresistor  technology  [106f 


Figure  34:  Cyrano  Science's  prototype  residual  life  indicators  t106]  (A)  chemiresistors  for 
respirator  cartridges  (B)  the  integration  of  chemiresistors  or  electronic  noses  to  full  body 
protection  gear  (C)  electronic  nose  chip 


The  US  Army  Edgewood  Chemical  and  Biological  Centre  (ECBC)  and  the  US  NRL  are 
currently  investigating  surface  acoustic  wave  (SAW)  sensors,  chemiresistor  sensors 
(CR)  and  photo-ionization  detectors  (PID)  as  possible  respirator  ESLI  [107f  Preliminary 
tests  have  shown  that  these  sensor  technologies  can  detect  dimethyl  methylphosphate 
(DMMP),  a  nerve  agent  simulant  t107'  108f  Further  information  regarding  the  mode  of 
operation  of  these  chemical  microsensors  is  covered  in  Part  II,  in  this  series  of  reports. 


25 


DSTO-TN-0657 


Furthermore,  ECBC  and  NRL  are  currently  evaluating  colourimetric  indicator 
films  I109],  patented  by  ChemMotif  Inc.  t™],  to  qualitatively  detect  the  presence  of 
various  organic  vapours  in  a  carbon  bed  t107].  The  novelty  of  these  indicator  films  is  that 
they  employ  a  displaceable  dye  to  indicate  the  presence  of  organic  vapours.  A  colour 
change  occurs  when  the  dye  becomes  displaced  by  the  contaminant  and  diffuses  into  a 
receiving  layer  where  it  can  be  seen  (Figure  35).  These  chemical  indicator  films  are 
currently  being  tested  on  a  broad  class  of  chemical  warfare  agents  and  toxic  industrial 
chemicals. 


v  ■  v$por 
d  ■  dye 


dye  visible 
through 
ptolic  base 


Figure  35:  Schematic  of  ChemMotif  s  dye  desorption  process  l110'  inl 


TNO  is  the  fourth  organisation  that  is  currently  performing  research  on  ESLIs.  The 
backbone  to  TNO's  respirator  ESLI  patent  in  1998,  was  the  desorption  of  an  odorant 
from  a  selected  region  within  the  carbon  bed,  which  subsequently  notified  the  user  (by 
smell)  that  the  cartridge  was  about  to  expire  (see  Section  2.3).  The  limitations  to  this 
original  design  included  differences  in  individual  olfactory  sensitivity  and  individual 
placebo  effects  towards  the  odorant  (see  Section  2.3).  Consequently,  TNO  has  been 
developing  an  optochemical  sensor  for  detecting  "the  release  of  a  so-called  signal 
compound"  t112]  (Figure  36).  Instead  of  an  odorant,  a  fluorescent  indicator  dye  is 
released  from  the  carbon,  which  is  then  detected  by  the  optochemical  sensor,  and  an 
alarm  is  subsequently  triggered.  Furthermore,  this  device  contains  a  pulsed  LED  and 
time-gated  circuitry,  which  significantly  reduces  the  energy  consumption  of  the  unit. 


26 


DSTO-TN-0657 


adsorption  front 


fiter  - 

gas  flow 

;  ►  Jl— 

ESLI  ^ 

signal  compound 
enters  detection 


usaJWa  End  c fsaw'tca  J.'tet™ 

Figure  36:  Schematic  ofTNO's  optochemical  sensor  for  detecting  the  release  of  a  fluorescent 
indicator  dye  t112l 


2.6  ESLIs  for  carbon  adsorption  beds. 

The  information  presented  in  the  earlier  sections  of  this  report  was  focused  on  ESLIs 
for  respirator  cartridges  or  canisters.  Conversely,  work  on  the  residual  life  or  the  end  of 
service  life  of  filter  beds  should  also  be  considered  as  potential  applications  for 
respirator  cartridges.  These  methods  are  briefly  discussed  below. 

In  1960,  Philip  t113]  reported  that  the  residual  life  of  carbon  adsorption  beds  could  be 
determined  by  passing  beta-radiation  through  the  adsorption  bed.  Unfortunately, 
applying  beta-radiation  through  a  respirator  cartridge  while  being  worn  is  impractical 
and  therefore  this  method  cannot  be  considered  as  an  ESLI. 

In  1994,  Martin  Marietta  Energy  Systems  patented  t114]  an  apparatus  and  method  for 
detecting  chemical  permeation  of  nerve,  blister  and  toxic  industrial  chemicals,  through 
protective  clothing.  The  patent  claims  that  phenanthrene  (a  strong  luminescing 
compound)  could  be  applied  to  detect  permeation  of  hazardous  chemicals  (which  do 
not  luminesce)  by  measuring  the  reduction  in  luminescence.  The  major  drawback  to 
this  design  was  the  absence  of  an  automatic  warning  device  for  notifying  the  user  that 
chemical  permeation  had  exceeded  acceptable  concentrations  but  instead 
concentrations  could  only  be  measured  with  a  portable  handheld  luminescence 
monitor.  In  addition,  a  major  concern  is  whether  personal  body  odour  permeation 
through  clothing  could  also  reduce  the  indicator's  luminesce.  Despite  these  concerns, 
this  indicator  system  may  have  the  potential  to  be  integrated  into  a  respirator  ESLI 
system. 

In  the  past  decade,  several  patents  have  been  awarded  on  determining  the  residual  life 
of  carbon-based  filters  by  measuring  the  heat  differentiation  during  gas 
adsorption/  desorption  [H5,ii6]  a  similar  method  was  applied  by  the  American  Optical 
Corporation  in  their  1979  respirator  ESLI  patent  t82]  (see  Section  2.4,  page  15  for 
discussion  on  the  drawbacks  in  measuring  adsorbent  temperature  changes  for 
monitoring  the  life  of  a  carbon  filter).  Unfortunately  these  procedures  are  only 
applicable  to  the  laboratory  where  the  rate  of  gas  being  fed  through  the  carbon  filter 
and  the  subsequent  heat  gains,  can  be  carefully  monitored.  Consequently,  these 
methods  cannot  be  applied  in  the  field;  in  particularly  while  the  respirator  cartridge  is 
worn. 


27 


DSTO-TN-0657 


2.7  Conclusions 

The  complexity  of  implementing  NIOSH's  recommended  cartridge  change  schedule  t62] 
is  best  summarised  by  an  official  statement  from  AOSafety  t117]. 

There  is  no  accurate,  reliable  method  established,  at  this  time,  for  determining  service  life  of 
a  cartridge  for  products  that  are  a  mixture  of  chemicals.  It  is  a  complex  task  that  requires 
considerable  professional  judgement  to  create  a  reasonable  change  schedule.  The  change 
schedule  for  a  mixture  should  be  based  on  reasonable  assumptions  that  include  a  margin  of 
safety  for  the  worker  wearing  the  respirator.  The  best  guesstimate  can  only  be  provided  if 
the  total  concentration  in  the  air  is  known.  Without  a  known  concentration,  the  service  life 
of  each  substance  identified  in  the  MSDS,  that  is  a  liquid  at  room  temperature,  must  be 
calculated  at  a  determined  concentration,  which  may  not  reflect  the  actual  concentration  of 
the  contaminants  in  the  air". 


Despite  extensive  work  in  the  art  of  ESLIs  for  respirator  cartridges,  none  of  the  designs 
encompass  the  capacity  to  simultaneously  detect  a  range  of  CW  agents  (nerve/ blister 
agents,  acid  gases  eg  HF,  HC1  etc)  or  hazardous  toxic  chemicals  (hydrocarbon  (eg 
benzene,  toluene)  or  chlorinated  hydrocarbon  vapours  (eg  carbon  tetrachloride))  (see 
Appendix,  page  39).  In  recent  years,  significant  innovative  advancements  in  chemical 
micro-sensory  technologies  have  transpired,  with  many  of  these  new  sensory  systems 
potentially  capable  of  concurrently  detecting  these  hazardous  agents  inside  the 
respirator  cartridge.  The  second  part  in  this  series  of  reports  will  embark  on  evaluating 
the  suitability  of  chemical  micro-sensors  towards  respirator  Active  End  of  Service  Life 
Indicators  (AESLI).  This  evaluation  will  be  aimed  at  providing  the  groundwork  for  the 
development  of  a  respirator  ESLI  suitable  for  defence  applications. 


28 


DSTO-TN-06 57 


3.  References 


1.  Wood,  G.  O.  (1994)  Estimating  service  lives  of  organic  vapor  cartridges. 
American  Industrial  Hygiene  Association  Journal,  55, 11-15. 

2.  Wood,  G.  O.  (1985)  Effects  of  air  temperatures  and  humidities  on  efficiencies 
and  lifetimes  of  air-purifying  chemical  respirator  cartridges  tested  against  methyl 
iodide.  American  Industrial  Hygiene  Association  Journal,  46,  251-256. 

3.  Ackley,  M.  W.  (1987)  Chemical  cartridge  respirator  performance:  1,3-butadiene. 
American  Industrial  Hygiene  Association  Journal,  48,  447-453. 

4.  Cohen,  H.  J.,  Zellers,  E.  T.,  and  Garrison,  R.  P.  (1990)  Development  of  a  field 
method  for  evaluating  the  service  lives  of  organic  vapor  cartridges:  Results  of 
laboratory  testing  using  carbon  tetrachloride.  Part  II:  Humidity  effects.  American 
Industrial  Hygiene  Association  Journal,  51,  575-580. 

5.  Nelson,  G.  O.,  Correia,  A.  N.,  and  Hardner,  C.  A.  (1976)  Respirator  cartridge 
efficiency  studies:  VII.  Effect  of  relative  humidity  and  temperature.  American 
Industrial  Hygiene  Association  Journal,  37,  280-288. 

6.  Nelson,  G.  O.,  and  Hardner,  C.  A.  (1972)  Respirator  cartridge  efficiency  studies 
IV.  Effects  of  steady-state  and  pulsating  flow.  American  Industrial  Hygiene 
Association  Journal,  33,  797-805. 

7.  Potorzhinskii,  I.,  and  Serpionova,  E.  (1970)  Adsorption  of  vapours  of  organic 
solvents  from  a  stream  of  moist  air  by  activated  carbon.  Tr.  Mosk.  Khim.  Tekhnol.  Inst., 
65,  79-82. 


8.  Adams,  L.  B.,  Hall,  C.  R.,  Holmes,  R.  J.,  and  Newton,  R.  A.  (1988)  An 
examination  of  how  exposure  to  humid  air  can  result  in  changes  in  the  adsorption 
properties  of  activated  carbons.  Carbon,  26,  451-459. 

9.  Yoon,  Y.  H.,  and  Nelson,  J.  H.  (1990)  Effects  of  humidity  and  contaminant 
concentration  on  respirator  cartridge  breakthrough.  American  Industrial  Hygiene 
Association  Journal,  51,  202-209. 

10.  Yoon,  Y.  H.,  and  Nelson,  J.  H.  (1988)  A  theoretical  study  of  the  effect  of 
humidity  on  respirator  cartridge  service  life.  American  Industrial  Hygiene  Association 
Journal,  49,  325-332. 

11.  Mix,  T.  W.,  and  McDonald,  T.  C.  (1990)  A  vapor  challenge  method  of  measuring 
the  residual  life  of  gas  filters,  CDREC-CR-086,  Chemical  Research,  Development  and 
Engineering  Center  (U.S.). 

12.  Moyer,  E.  S.,  and  Berardinelli,  S.  P.  (1987)  Penetration  of  methyl  isocyanate 
through  organic  vapor  and  acid  gas  respirator  cartridges.  American  Industrial  Hygiene 
Association  Journal,  48,  315-323. 


29 


DSTO-TN-0657 


13.  Johnson,  E.  (2002)  Predicting  the  effect  of  high  relative  humidity  on  organic 
vapor  cartridge  performance.  3M  JobHealth  Highlights,  20, 1-3. 

14.  Brey,  L.  A.,  and  Johnson,  E.  W.  (2001)  Prediction  of  the  effect  of  high  relative 
humidity  on  organic  vapor  cartridge  performance,  American  Industrial  Hygiene 
Conference  and  Exposition,  New  Orleans,  Louisiana 

15.  Wood,  G.  O.,  and  Lodewyckx,  P.  (2003)  An  extended  equation  for  rate 
coefficients  for  adsorption  of  organic  vapors  and  gases  on  activated  carbons  in  air- 
purifying  respirator  cartridges.  American  Industrial  Hygiene  Association  Journal,  64, 
646-650. 

16.  Cohen,  H.  J.,  Levine,  S.  P.,  and  Garrison,  R.  P.  (1991)  Development  of  a  field 
method  for  determining  the  service  lives  of  respirator  cartridges  -  Part  IV:  Results  of 
field  validation  trials.  American  Industrial  Hygiene  Association  Journal,  52,  263-270. 

17.  Yoon,  Y.  H.,  Nelson,  J.  H.,  Lara,  J.,  Kamel,  C.,  and  Fregeau,  D.  (1991)  A 
theoretical  interpretation  of  the  service  life  of  respirator  cartridges  for  the  binary 
acetone/ m-xylene  system.  American  Industrial  Hygiene  Association  Journal,  52,  65-74. 

18.  Yoon,  Y.  H.,  Nelson,  J.  H.,  Lara,  J.,  Kamel,  C.,  and  Fregeau,  D.  (1992)  A 
theoretical  model  for  respirator  cartridge  service  life  for  binary  systems:  Application  to 
acetone/ styrene  mixtures.  American  Industrial  Hygiene  Association  Journal,  53,  493- 
502. 

19.  Robbins,  C.  A.,  and  Breysse,  P.  N.  (1996)  The  effect  of  vapor  polarity  and  boiling 
point  on  breakthrough  for  binary  mixtures  on  respirator  carbon.  American  Industrial 
Hygiene  Association  Journal,  57,  717-723. 

20.  Yoon,  Y.  H.,  Nelson,  J.  H.,  and  Lara,  J.  (1996)  Respirator  cartridge  service-life: 
Exposure  to  mixtures.  American  Industrial  Hygiene  Association  Journal,  57,  809-819. 

21.  Wood,  G.  O.,  and  Stampfer,  J.  F.  (1993)  Adsorption  rate  coefficients  for  gases 
and  vapors  on  activated  carbons.  Carbon,  31, 195-200. 

22.  Nelson,  G.  O.,  and  Hardner,  C.  A.  (1974)  Respirator  cartridge  efficiency  studies: 

V.  Effect  of  solvent  vapor.  American  Industrial  Hygiene  Association  Journal,  35,  391- 
410. 

23.  Nelson,  G.  O.,  and  Hardner,  C.  A.  (1976)  Respirator  cartridge  efficiency  studies 

VI.  Effect  of  concentration.  American  Industrial  Hygiene  Association  Journal,  37,  205- 
216. 

24.  Swearengen,  P.  M.,  and  Weaver,  S.  C.  (1988)  Respirator  cartridge  study  using 
organic-vapor  mixtures.  American  Industrial  Hygiene  Association  Journal,  49,  70-74. 

25.  Nelson,  G.  O.,  and  Correia,  A.  N.  (1976)  Respirator  cartridge  efficiency  studies: 
VIII.  Summary  and  conclusions.  American  Industrial  Hygiene  Association  Journal,  37, 
514-525. 


30 


DSTO-TN-06 57 


26.  Osmond,  N.  M.,  and  Phillips,  P.  L.  (2001)  Pressure  drop  and  service  life 
predictions  for  respirator  canisters.  American  Industrial  Hygiene  Association  Journal, 
62,  288-294. 

27.  Silverman,  L.,  Lee,  G.,  Plotkin,  T.,  Sawyers,  L.  A.,  and  Yancey,  A.  R.  (1951)  Air 
flow  measurements  on  human  subjects  with  and  without  respiratory  resistance  at 
several  work  rates.  American  Medical  Association  Archives  of  Industrial  Hygiene  and 
Occupational  Medicine,  3,  461-478. 

28.  Peterson,  R.  L.,  Beaumont,  G.  P.,  and  Johnson,  B.  P.  (1980)  Process  for  predicting 
the  useful  life  of  a  respirator  cartridge.  The  Dow  Chemical  Company,  Patent  No. 
US4237726. 

29.  Yoon,  Y.  H.,  and  Nelson,  J.  H.  (1984)  Application  of  gas  adsorption  kinetics  -  II. 

A  theoretical  model  for  respirator  cartridge  service  life  and  its  practical  applications. 

American  Industrial  Hygiene  Association  Journal,  45,  517-524. 

30.  Yoon,  Y.  H.,  and  Nelson,  J.  H.  (1992)  Breakthrough  time  and  adsorption 
capacity  of  respirator  cartridges.  American  Industrial  Hygiene  Association  Journal,  53, 
303-316. 

31.  Nelson,  T.  J.,  and  Janssen,  L.  L.  (1999)  Developing  cartridge  change  schedules: 
What  are  the  options?  3M  JobHealth  Highlights,  17. 

32.  Reist,  P.,  and  Rex,  F.  (1977)  Odor  detection  and  respirator  cartridge 

replacement.  American  Industrial  Hygiene  Association  Journal,  38,  563-566. 

33.  National  Institute  for  Occupational  Safety  and  Health  (NIOSH).  A  guide  to 
industrial  respiratory  protection.  (1976)  Cincinnati,  OH 

34.  Using  air-purifying  respirators  for  protection  against  isocyanates  under 

OSHA's  new  respiratory  protection  standard  -  Validation  for  cartridge/ canister 
cartridge  change  schedules  (Attachment  2),  Using  air-purifying  respirators  for 
protection  against  isocyanates  under  OSHA's  new  respiratory  protection  standard  - 
Validation  for  cartridge/ canister  cartridge  change  schedules  (Attachment  2),  29  C.F.R. 
1910.134. 

35.  Corbitt,  S.  M.,  Heger,  E.  A.,  and  Sarvadi,  D.  G.  (2002)  Use  of  air-purifying 
respirators  for  substances  with  limited  or  poor  warning  properties.  Isocyanates: 
Sampling,  Analysis,  and  Health  Effects,  ASTM  STP  1408,  Vol.,  American  Society  for 
Testing  and  Materials,  West  Conshohocken,  PA,  United  States. 

36.  Dower,  J.  M.,  Metzler,  R.  W.,  Palya,  F.  M.,  Peterson,  J.  A.,  and  Harner,  M.  P. 
(2000)  NIOSH-DOD-OSHA  sponsored  Chemical  and  biological  respiratory  protection 
workshop  report,  2000-122,  U.S.  Department  of  Health  and  Human  Services  (National 
Institute  for  Occupational  Safety  and  Health). 


31 


DSTO-TN-0657 


37.  Vincent,  J.  B.  (2002)  ASReal-time  end-of-service-life  indicators  will  increase 
reliability  of  determining  cartridge  service  life.  Industrial  Hygiene  News,  Article 
Archive,  September  2002. 

38.  Yablick,  M.  (1925)  Indicating  gas-mask  canister.  Patent  No.  US1537519. 

39.  Yablick,  M.  (1929)  Indicating  gas-mask  canister.  Mine  Safety  Appliances  Co, 
Patent  No.  US1725893. 

40.  Dragerwerk,  H.,  and  Bernh,  D.  L.  (1957),  Patent  No.  GE962313. 

41.  Wiswesser,  W.  J.  (1960)  Window  canister  assembly.  Electric  Storage  Battery  Co., 
Patent  No.  US2961303. 

42.  Roberts,  C.  C.  (1976)  Colorimetric  vinyl  chloride  indicator.  Catalyst  Research 
Corporation,  Patent  No.  US3966440. 

43.  Wing,  R.  E.  (1982)  Filter-type  respirator  canister.  The  Dow  Chemical  Company, 
Patent  No.  US4365627. 

44.  Brauer,  L.  W.  (1978)  Combination  of  a  supplementary  filter  and  respirator  filter, 
Auergesellschaft  GMBH,  Patent  No.  US4088461. 

45.  McAllister,  J.  W„  Ord,  J.  A.  J.,  Anders,  L.  W„  and  Kohler,  G.  A.  (1979) 
Respirator,  Minnesota  Mining  and  Manufacturing  Company,  Patent  No.  US4155358. 

46.  Jones,  J.  A.,  and  Ayes,  A.  V.  (1979)  Respirator  cartridge  end-of-service  lift 
indicator  system  and  method  of  making,  American  Optical  Corporation,  Patent  No. 
US4154586. 

47.  Corporation,  A.  O.  (1979)  Respirator  cartridges,  American  Optical  Corporation, 
Patent  No.  GB1554542. 

48.  Tanaka,  S.,  Tsuda,  Y.,  Kitamura,  S.,  and  Shimada,  M.  (2001)  A  simple  method 
for  detecting  breakthroughs  in  used  chemical  cartridges.  American  Industrial  Hygiene 
Association  Journal,  62, 168-171. 

49.  Japanese  Industrial  Standard  (JIS)  :  Gas  masks.  (1981)  JIS  T  8152  Standard, 
Tokyo:  Japanese  Standard  Association 

50.  Jones,  J.  A.  (1985)  Respirator  cartridge  end-of-service  life  indicator,  American 
Optical  Corporation,  Patent  No.  US4530706. 

51.  Eian,  G.  L.  (1981)  Cartridge  respirator  with  service  life  indicator,  Minnesota 
Mining  and  Manufacturing  Company,  Patent  No.  EP0042736. 

52.  Eian,  G.  L.  (1982)  Cartridge  respirator  with  service  life  indicator,  Minnesota 
Mining  and  Manufacturing  Company,  Patent  No.  US4326514. 


32 


DSTO-TN-0657 


53.  Heijenga,  B.,  Hilbrink,  H.  E.,  and  Klaij,  H.  F.  (1984)  Detector  for  detecting  air 
components,  TNO,  Patent  No.  US4428907. 

54.  Leichnitz,  K.  (1986)  A  filter  apparatus  having  a  monitor  for  indicating  the  state 
of  exhaustion  of  the  filter,  Draegerwerk  AG,  Patent  No.  GB2168259. 

55.  Leichnitz,  K.  (1987)  Colorimetric  indicator  for  the  indication  of  the  exhaustion 
of  gas  filters,  Dragerwerk  AG,  Germany,  Patent  No.  US4684380. 

56.  Fehlauer,  K.  U.  (1994)  Breathing  mask  with  an  indicator  signalling  penetration 
of  a  toxic  substance  into  the  mask,  Dragerwerk  AG,  Patent  No.  US5323774. 

57.  Haddington,  D.  W.  (1995)  Respiratory  filter  indicator,  Purecab  Australia  Pty 
Ltd,  Patent  No.  W09512432. 

58.  Curado,  L.,  and  deMedeiros,  E.  (2002)  Respirator  cartridge  with  service  life 
indicator.  North  Safety  Products,  Inc.,  Patent  No.  WO0222237A1. 

59.  Curado,  L.,  and  deMedeiros,  E.  (2002)  Service  life  indicator  for  respirator 
cartridge.  North  Safety  Products,  Inc.,  Patent  No.  US6497756  Bl. 

60.  Watson,  E.  J.,  Caraher,  T.  W.,  Bennett,  M.  R.,  Roehl,  J.  E.,  Greenfield,  M.  J.,  and 
Ericsson,  A.  J.  (2004)  Residual  Life  Indicator,  Scentczar  Corporation,  Patent  No. 
US6701864. 

61.  Watson,  E.  J.,  Caraher,  T.  W.,  Bennett,  M.  R.,  Roehl,  J.  E.,  Greenfield,  M.  J.,  and 
Ericsson,  A.  J.  (2003)  Residual  Life  Indicator,  Scentczar  Corporation,  Patent  No. 
WO03028842. 

62.  Regulations  predating  the  January  1998  OSHA  Revision,  Regulations  predating 
the  January  1998  OSHA  Revision,  Federal  Register,  63,  29  C.F.R.  1910.134,  Jan  8,  1998, 
1152 

63.  Metzler,  R.  W.  (2002)  Withdrawal  of  Aearo  Company's  full  facepiece  respirators 
with  the  R59A  mercury  vapor/ chlorine  cartridge.  National  Institute  fro  Occupational 
Safety  and  Health. 

64.  (2004)  North  Safety  Products  homepage,  http:/ / www.northsafety.com. 

65.  NIOSH  (1998)  White  paper:  respirators.  Control  of  Workplace  Hazards  for  the 
21st  Century:  Setting  the  Research  Agenda,  Chicago,  Illinois. 

66.  Wollin,  K.,  Smolczyk,  E.,  and  Engelhard,  H.  (1932)  Method  for  indicating  the 
exhaustion  of  substances  used  for  cleaning  gases,  Gasgluhlicht  Auer  Gmbh  Deutsch, 
Patent  No.  US1845000. 


33 


DSTO-TN-0657 


67.  Jager,  H.,  and  Van  de  Voorde,  M.  J.  (1998)  Device  for  removing  one  or  more 

undesirable  or  dangerous  substances  from  a  gas  or  vapor  mixture  and  a  gas  mask 
comprising  such  a  device,  Nederlandse  Organisatie  Voor 

Toegepastnatuurwetenschappelijk  Onderzoek  TNO,  Patent  No.  EP0838243. 

68.  Jager,  H.,  and  Van  de  Voorde,  M.  J.  (1999)  Device  for  removing  one  or  more 

undesirable  or  dangerous  substances  from  a  gas  or  vapor  mixture  and  a  gas  mask 
comprising  such  a  device,  Nederlandse  Organisatie  Voor 

Toegepastnatuurwetenschappelijk  Onderzoek  TNO,  Patent  No.  US5944873. 

69.  Jager,  H.,  Van  de  Voorde,  M.  J.,  and  van  Bokhoven,  J.  J.  G.  M.  (1999)  A  new 
principle  for  an  end  of  service  life  indicator.  International  Society  for  Respiratory 
Protection  conference,  Pittsburgh,  United  States 

70.  Linders,  M.  J.  G.,  Bal,  E.  A.,  Baak,  P.  J.,  Hoefs,  J.  H.  M.,  and  van  Bokhoven,  J.  J. 
G.  M.  (2001)  Further  develoment  of  an  end  of  service  life  indicator  for  activated  carbon 
filters.  Carbon  '01,  University  of  Kentucky  Center  for  Applied  Energy  Research, 
Lexington,  Kentucky,  United  States 

71.  Loscher,  R.  A.  (1965)  Gas  contaminant  sensing  device,  Selas  Corp  of  America, 
Patent  No.  US3200387. 

72.  Wallace,  R.  A.  (1973)  Chemical  breathing  apparatus  with  alarm  device,  Wallace, 
R.  A,  Patent  No.  US3773044. 

73.  Bovard,  R.  M.  (1960)  Oxygen  producing  canister.  Mine  Safety  Appliances 
Company,  Patent  No.  GB856910. 

74.  Lemcke,  W.  K.,  and  Reeck,  H.  E.  (1968)  Oxygen  producing  canister, 
Auergesellschaft  GMBH,  Patent  No.  US3403981. 

75.  Jackson,  C.  B.,  and  Andel,  A.  C.  V.  (1950)  Oxygen  liberating  canister.  Mine 
Safety  Appliances  Company,  Patent  No.  US2517209. 

76.  Beahm,  H.  C.,  Jackson,  C.  B.,  and  Andel,  A.  C.  V.  (1950)  Oxygen  generating 
canister.  Mine  Safety  Appliances  Company,  Patent  No.  US2494131. 

77.  Bovard,  R.  M.  (1959)  Oxygen  producing  canister.  Mine  Safety  Appliances 
Company,  Patent  No.  US2913317. 

78.  Bovard,  R.  M.  (1959)  Oxygen  producing  canister  for  breathing  apparatus, 
M.S.A.  Research  Corp.,  Patent  No.  US2889210. 

79.  Wallace,  R.  A.  (1975)  Chemically  activated  warning  system,  Wallace,  R.  A., 
Patent  No.  US3902485. 

80.  Wallace,  R.  A.  (1975)  Thermally  activated  warning  system,  Wallace  R.  A.,  Patent 
No.  US3911413. 


34 


DSTO-TN-0657 


81.  NIOSH  (1978)  Development  of  a  prototype  service-life  indicator  for  organic 
vapor  respirators,  PB91 -136309,  NIOSH,  Cincinnati,  OH,  USA. 

82.  Magnante,  P.  C.  (1979)  Respirator  cartridge  end-of-service  life  indicator, 
American  Optical  Corporation,  Patent  No.  US4146887. 

83.  National  Institute  for  Occupational  Safety  and  Health  (NIOSH),  Notice  of 
acceptance  of  applications  for  approval  of  air  purifying  respirators  with  end-of-service- 
life  indicators  (ESLI),  Federal  Register,  49, 140,  July  19, 1984,  29270-29272. 

84.  Freidank,  M.,  Coym,  J.,  and  Schubert,  A.  (1989)  Warning  device  to  indicate  the 
state  of  gases  exhaustion  of  a  gas  filter  retaining  dangerous  gases,  Auergesellschaft 
GMBH,  Patent  No.  US4873970. 

85.  Coym,  J.,  Freidank,  M.,  and  Schubert,  A.  (1987)  Warning  device  for  indicating 
the  state  of  exhaustion  of  a  gas  filter,  Auergesellschaft  GMBH,  Patent  No.  EP0246444. 

86.  Stetter,  J.  R.  (1989)  Sensor  for  detecting  the  exhaustion  of  an  adsorbent  bed. 
Transducer  Research  Inc.,  Patent  No.  US4847594. 

87.  Stetter,  J.  R.  (1990)  Exhaustion  sensor  and  indicator  e.g.  for  face  mask  -  gives 
real-time  warning  of  saturation  of  absorbent  material  by  measurement  of  electrical 
conductivity  of  coating,  Stetter  J.,  Patent  No.  DE3914664. 

88.  Maclay,  G.  J.,  Yue,  C.,  Findlay,  M.  W.,  and  Stetter,  J.  R.  (1991)  A  prototype  active 
end-of-service-life  indicator  for  respirator  cartridges.  Applied  Occupational  and 
Environmental  Hygiene,  6,  677-682. 

89.  Moyer,  E.  S.,  Findlay,  M.  W.,  Maclay,  G.  J.,  and  Stetter,  J.  R.  (1993)  Preliminary 
evaluation  of  an  active  end-of-service-life  indicator  for  organic  vapor  cartridge 
respirators.  American  Industrial  Hygiene  Association  Journal,  54, 417-425. 

90.  Stetter,  J.  R.,  and  Maclay,  G.  J.  (1996)  Chemical  sensing  apparatus  and  methods. 
Transducer  Research  Inc.,  Patent  No.  US5512882. 

91.  Hubner,  H.  J.  (1991)  Gas  work  with  sensing  and  alarm  means,  Geraetebau 
GMBH,  Patent  No.  US5018518. 

92.  May,  W.,  Bather,  W.,  van  der  Smissen,  C.  E.,  and  Muhmel,  G.  (1994)  Respirator 
with  inner  half  mask  and  pollutant  indicator,  Dragerwerk  AG,  Patent  No.  US5297544. 

93.  Debe,  M.  K.,  Yuschak,  G.,  Parsonage,  E.  E.,  Poirier,  R.  J.,  and  Miller,  L.  R.  (1996) 
Exposure  Indicating  Apparatus,  Minnesota  Mining  and  Manufacturing  Company, 
Patent  No.  W09612524. 

94.  Debe,  M.  K.,  Yuschak,  G.,  Parsonage,  E.  E.,  Poirier,  R.  J.,  and  Miller,  L.  R.  (1997) 
Exposure  indicating  apparatus,  Minnesota  Mining  and  Manufacturing  Company, 
Patent  No.  US5659296. 


35 


DSTO-TN-0657 


95.  Bernard,  P.,  Caron,  S.,  St.Pierre,  M.,  and  Lara,  J.  (1998)  End-of-service  indicator 
for  a  respirator  cartridge,  Institut  National  D'Optique,  Quebec,  Patent  No.  EP1032823. 

96.  Bernard,  P.,  Caron,  S.,  St.Pierre,  M.,  and  Lara,  J.  (1999)  End-of-service  indicator 
for  a  respirator  cartridge,  Institut  National  D'Optique,  Quebec,  Patent  No.  W09927352. 

97.  Bernard,  P.,  Caron,  S.,  St.Pierre,  M.,  and  Lara,  J.  (2002)  End-of-service  indicator 
including  porous  waveguide  for  respirator  cartridge,  Institut  National  D'Optique, 
Quebec,  Patent  No.  US6375725. 

98.  Gordik,  N.  M.  (2001)  Dynamic  apparatus  for  determining  time  of  protective 
effect  of  gas  mask  boxes  and  respirators,  Novosib  Z  Aoot,  Avod  Khimkontsentratov, 
Patent  No.  RU2174420. 

99.  Wu,  T.,  Li,  Q.,  Li,  S.,  Wan,  C.,  Lin,  B.,  She,  Q.,  Zhang,  Q.,  Chen,  S.,  Zhong,  T., 
Zhao,  H.,  Wang,  J.,  and  Wu,  L.  (2001)  Filter-mask  with  expiry  indication  for  organic 
toxic  gas.  Health  and  Epidemic  Prevention  Station,  Patent  No.  CN1281738. 

100.  Shigematsu,  Y.,  Kurano,  R.,  and  Shimada,  S.  (2002)  Gas  mask  having  detector 
for  detecting  timing  to  exchange  absorption  can,  Shigematsu  Works  Co  Ltd  and  New 
Cosmos  Electric  Corp.,  Patent  No.  JP2002102367. 

101.  Hori,  H.,  Ishidao,  T.,  and  Ishimatsu,  S.  (2003)  Development  of  a  new  respirator 
for  organic  vapors  with  a  breakthrough  detector  using  a  semiconductor  gas  sensor. 
Applied  Occupational  and  Environmental  Hygiene,  18,  90-95. 

102.  Hori,  H.,  Noritake,  Y.,  Murobushi,  H.,  Higashi,  T.,  and  Tanaka,  I.  (1999)  A 
method  of  detecting  breakthrough  of  organic  solvent  vapors  in  a  charcoal  tube  using 
semiconductor  gas  sensors.  Applied  Occupational  and  Environmental  Hygiene,  14, 
558-564. 

103.  Roehl,  J.  E.,  Caraher,  T.  W.,  Kalmes,  K.  A.,  and  Isley,  E.  A.  (2000)  Residual  life 
indicators  -  point  chemical  detectors  used  to  measure  the  capacity  of  activated  carbon 
in  protective  garments,  gas  mask  filters,  and  collective  protection  filters.  Proceedings  of 
the  First  Joint  Conference  on  Point  Detection  for  Chemical  and  Biological  Defense, 
Williamsburg,  VA. 

104.  Stetter,  J.  R.,  and  Penrose,  W.  R.  (2002)  Understanding  chemical  sensors  and 
chemical  sensor  arrays  (electronic  noses):  Past,  present  and  future.  Sensors  Update,  10, 
189-229. 

105.  Lewis,  N.  S.,  Dixson,  J.,  Grubbs,  R.  H.,  and  Goodman,  R.  M.  (2003)  Techniques 
and  systems  for  analyte  detection,  Cyrano  Sciences  Inc,  Patent  No.  NZ504675. 

106.  Cyrano  Sciences,  Array  based  chemiresistor  sensors  for  residual  life  and  end  of 
service  life  indication,  NIOSH  presentation.  (2002) 


36 


DSTO-TN-0657 


107.  Gardner,  P.,  McGill,  R.  A.,  Lawhon,  S.,  Weir,  D.  W.,  Greenblatt,  J.,  Chung,  R., 
and  Tevault,  D.  (2001)  End-of-service-life  indicators  for  NBC  protective  filters,  7th 
International  Symposium  on  Protection  against  Chemical  and  Biological  Warfare 
Agents,  Stockholm,  Sweden 

108.  Lewis,  N.  S.  (2002)  "Electronic  nose"  chip  microsensors  for  chemical  agent 
detection,  23rd  Army  science  conference,  Orlando,  Florida 

109.  Gardner,  P.  D.  (2002)  Development  of  an  end-of-service-life  indicator  for  NBC 
mask  filters,  23rd  Army  science  conference,  Orlando,  Florida 

110.  Spitler,  M.  T.,  and  Stuhl,  L.  S.  (2000)  Dye  desorption  molecular  indicator, 
Chemmotif,  Inc.,  Patent  No.  W00003226. 

111.  (2004)  ChemMotif  Technology  homepage, 
http:  /  /  www.chemmotif.com/technology.htm. 

112.  (2004)  End  of  service  life  indicator  (ESLI)  device  for  gas  filters,  TNO  Nutrition 
and  Food  Research  product  sheet. 

113.  Philip,  M.  (1960)  Method  and  apparatus  for  predicting  the  residual  life  of 
adsorption  beds,  Walter  Kidde  Nuclear  Lab  Inc,  Patent  No.  US2951156. 

114.  Vo-Dinh,  T.  (1994)  Apparatus  and  methods  for  detecting  chemical  permeation, 
Martin  Marietta  Energy  Systems,  Patent  No.  US5376554. 

115.  Smith,  M.  W.,  and  Rhys,  M.  J.  (2001)  Method  and  apparatus  for  determining  the 
residual  life  of  filters,  SECR  Defence,  Patent  No.  W00183083  Al. 

116.  Sawada,  S.,  Shiraishi,  T.,  Sakuratani,  T.,  and  Shintani,  K.  (2000)  Method  for 
judging  residual  life  of  filter  for  adsorbing  organic  gas,  Unitika  Ltd.,  Patent  No. 
JP2000218158. 

117.  Tetreault,  A.  (2004)  Cartridge  service  life,  AOSafety  -  respirator  cartridge 
brochure  information. 


37 


DSTO-TN-0657 


38 


DSTO-TN-06 57 


Appendix  A:  Documented  respirator  ESLI  mediums 


Agents  and  type  of  indicator  used  on  respirator  cartridges  for  determining  the  end  of  service  life 

of  the  unit. 


Gas/ agent 

Indicator 

Colour  change 

Reference 

Ammonia 

Red  litmus 

Red  to  blue 

[39] 

Hydrogen  sulphide 

Congo  red  soln. 

Red  to  blue 

[39] 

Hydrochloric  acid 

Congo  red  soln. 

Red  to  blue 

[39] 

Sulphur  dioxide 

Congo  red  soln. 

Red  to  blue 

[39] 

Carbon  monoxide 

Palladium  chloride 

Brown-red  to  black 

[39] 

Vinyl  chloride 

Potassium  permanganate 

Purple  to  brown 

[42,  45] 

2-butanone 

Na2Cr20z 

Orange  to  dark  green 

[47] 

1,1,1-trichloroethane 

Na2Cr2C>7 

Orange  to  dark  green 

[47] 

Benzene 

Na2Cr2C>7 

Orange  to  dark  green 

[47] 

S02 

Indophenol 

Dark  blue  to  white 

[52] 

Chlorine 

Indophenol 

Dark  blue  to  white 

[52] 

Chlorine 

Benzoyl  leuco  methylene  blue 

White  to  blue 

[52] 

Acrylonitrile 

Potassium  permanganate 

Purple  to  brown 

[52] 

Acetone 

fibre  optic  chemical  sensor 

Decrease  in  light  intensity 

[95,  96] 

Toluene 

fibre  optic  chemical  sensor 

Decrease  in  light  intensity 

[95,  96] 

39 


DISTRIBUTION  LIST 


End  of  Service  Life  Indicators  (ESLI)  for  respirator  cartridges 

George  Favas 

AUSTRALIA 


DEFENCE  ORGANISATION 
Task  Sponsor 
DGLD 

S&T  Program 

Chief  Defence  Scientist 

FAS  Science  Policy 

AS  Science  Corporate  Management 

Director  General  Science  Policy  Development 

Counsellor  Defence  Science,  London 

Counsellor  Defence  Science,  Washington 

Scientific  Adviser  to  MRDC,  Thailand 

Scientific  Adviser  Joint 

Navy  Scientific  Adviser 

Scientific  Adviser  -  Army 

Scientific  Adviser  to  the  DMO 


Platforms  Sciences  Laboratory 

Director 

Head  of  CBRN  Defence  Centre 
Research  Leader 
Head:  Dr  Simon  Oldfield 
Task  Manager:  Mr  Steven  Scanlon 
Author(s):  Dr  George  Favas 

DSTO  Library  and  Archives 

Library  Fishermans  Bend 
Library  Edinburgh 
Defence  Archives 
Library,  Sydney 
Library,  Stirling 
Library  Canberra 


No.  of  copies 


1  Printed 

1 

1 

1 

1 

Doc  Data  Sheet 
Doc  Data  Sheet 
Doc  Data  Sheet 
1 

Doc  Data  Sht  &  Dist  List 
Doc  Data  Sht  &  Dist  List 
Doc  Data  Sht  &  Dist  List 
1 


Doc  Data  Sht  &  Exec 
Summ 

Doc  Data  Sht  &  Dist  List 
Doc  Data  Sht  &  Dist  List 
1  Printed 
1  Printed 
1  Printed 

Doc  Data  Sheet 
1  Printed 
1  Printed 
Doc  Data  Sheet 
Doc  Data  Sheet 
Doc  Data  Sheet 


Capability  Development  Group 

Director  General  Maritime  Development 

Director  General  Land  Development 

Director  General  Integrated  Capability  Development 

Director  General  Capability  and  Plans 

Assistant  Secretary  Investment  Analysis 

Director  Capability  Plans  and  Programming 

Director  General  Australian  Defence  Simulation  Office 

Chief  Information  Officer  Group 

Director  General  Australian  Defence  Simulation  Office 
Director  General  Information  Policy  and  Plans 
AS  Information  Strategy  and  Futures 
AS  Information  Architecture  and  Management 
Director  General  Information  Services 

Strategy  Group 

Director  General  Military  Strategy 
Assistant  Secretary  Strategic  Policy 

Assistant  Secretary  Governance  and  Counter-Proliferation 
Navy 

Maritime  Operational  Analysis  Centre,  Building  89/90  Garden  Island 
Sydney  NSW 

Deputy  Director  (Operations) 

Deputy  Director  (Analysis) 

Director  General  Navy  Capability,  Performance  and  Plans,  Navy 
Headquarters 

Director  General  Navy  Strategic  Policy  and  Futures,  Navy 
Headquarters 

Air  Force 

SO  (Science)  -  Headquarters  Air  Combat  Group,  RAAF  Base, 
Williamtown  NSW  2314 

Army 

ABCA  National  Standardisation  Officer 

SO  (Science)  -  Land  Headquarters  (LHQ),  Victoria  Barracks  NSW 

SO  (Science),  Deployable  Joint  Force  Headquarters  (DJFHQ)  (L), 
Enoggera  QLD 

Joint  Operations  Command 

Director  General  Joint  Operations 

Chief  of  Staff  Headquarters  Joint  Operations  Command 
Commandant  ADF  Warfare  Centre 


Doc  Data  Sheet 
1 
1 

Doc  Data  Sheet 
Doc  Data  Sheet 
Doc  Data  Sheet 
Doc  Data  Sheet 

Doc  Data  Sheet 
Doc  Data  Sheet 
Doc  Data  Sheet 
Doc  Data  Sheet 
Doc  Data  Sheet 

Doc  Data  Sheet 
Doc  Data  Sheet 
Doc  Data  Sheet 

Doc  Data  Sht  &  Dist  List 


Doc  Data  Sheet 
Doc  Data  Sheet 


Doc  Data  Sht  &  Exec 
Summ 


e-mailed  Doc  Data  Sheet 

Doc  Data  &  Exec 
Summary 
Doc  Data  Sheet 


Doc  Data  Sheet 
Doc  Data  Sheet 
Doc  Data  Sheet 


Director  General  Strategic  Logistics 
COS  Australian  Defence  College 


Doc  Data  Sheet 
Doc  Data  Sheet 


Intelligence  and  Security  Group 

AS  Concepts,  Capability  and  Resources 
DGSTA ,  DIO 

Manager,  Information  Centre,  Defence  Intelligence  Organisation 
Assistant  Secretary  Capability  Provisioning 
Assistant  Secretary  Capability  and  Systems 

Defence  Materiel  Organisation 

Deputy  CEO 

Head  Aerospace  Systems  Division 
Head  Maritime  Systems  Division 
Head  Electronic  and  Weapon  Systems  Division 
Program  Manager  Air  Warfare  Destroyer 

Defence  Libraries 

Library  Manager,  DLS-Canberra 

OTHER  ORGANISATIONS 

National  Library  of  Australia 
NASA  (Canberra) 

Library  of  New  South  Wales 
State  Library  of  South  Australia 

UNIVERSITIES  AND  COLLEGES 
Australian  Defence  Force  Academy 

Library 

Head  of  Aerospace  and  Mechanical  Engineering 
Serials  Section  (M  list),  Deakin  University  Library,  Geelong,  VIC 
Hargrave  Library,  Monash  University 
Librarian,  Flinders  University 

OUTSIDE  AUSTRALIA 


1 

1  Printed 
1 

Doc  Data  Sheet 
Doc  Data  Sheet 

Doc  Data  Sheet 
Doc  Data  Sheet 
Doc  Data  Sheet 
Doc  Data  Sheet 
Doc  Data  Sheet 


Doc  Data  Sheet 

1 

1 

1 

1 


1 

1 

1 

Doc  Data  Sheet 
1 


INTERNATIONAL  DEFENCE  INFORMATION  CENTRES 

US  Defense  Technical  Information  Center  1 

UK  Dstl  Knowledge  Services  1 

Canada  Defence  Research  Directorate  R&D  Knowledge  &  Information  1 
Management  (DRDKIM) 

NZ  Defence  Information  Centre  1 

ABSTRACTING  AND  INFORMATION  ORGANISATIONS 

Library,  Chemical  Abstracts  Reference  Service  1 

Engineering  Societies  Library,  US  1 

Materials  Information,  Cambridge  Scientific  Abstracts,  US  1 

Documents  Librarian,  The  Center  for  Research  Libraries,  US  1 


SPARES 


5  Printed 


Total  number  of  copies:  38  Printed:  12  PDF:  26 


Page  classification:  UNCLASSIFIED 


DEFENCE  SCIENCE  AND  TECHNOLOGY  ORGANISATION 

DOCUMENT  CONTROL  DATA  i-  privacy  marking/ caveat  (of  document) 

2.  TITLE  3.  SECURITY  CLASSIFICATION  (FOR  UNCLASSIFIED  REPORTS 

THAT  ARE  LIMITED  RELEASE  USE  (L)  NEXT  TO  DOCUMENT 
End  of  Service  Life  Indicator  (ESLI)  for  Respirator  Cartridges.  Part  I:  CLASSIFICATION) 

Literature  Review 


Document 

(U) 

Title 

(U) 

Abstract 

(U) 

4.  AUTHOR(S)  5.  CORPORATE  AUTHOR 

George  Favas  DSTO  Defence  Science  and  Technology  Organisation 

506  Lorimer  St 

Fishermans  Bend  Victoria  3207  Australia 


6a.  DSTO  NUMBER 

6b.  AR  NUMBER 

6c.  TYPE  OF  REPORT 

7.  DOCUMENT  DATE 

DSTO-TN-O  657 

AR-013-478 

Technical  Note 

July  2005 

8.  FILE  NUMBER 

9.  TASK  NUMBER 

10.  TASK  SPONSOR 

11.  NO.  OF  PAGES 

12.  NO.  OF  REFERENCES 

2003/65565/1 

ARM  04/142 

DGLD 

40 

117 

13.  URL  on  the  World  Wide  Web  14.  RELEASE  AUTHORITY 


http: / / www.dsto.defence.gov.au/corporate/reports/DSTO-TN-0657.pdf  Chief,  Human  Protection  &  Performance  Division 

15.  SECONDARY  RELEASE  STATEMENT  OF  THIS  DOCUMENT 

Approved  for  public  release 

OVERSEAS  ENQUIRIES  OUTSIDE  STATED  LIMITATIONS  SHOULD  BE  REFERRED  THROUGH  DOCUMENT  EXCHANGE,  PO  BOX  1500,  EDINBURGH,  SA  5111 _ 

16.  DELIBERATE  ANNOUNCEMENT 

No  Limitations 

17.  CITATION  IN  OTHER  DOCUMENTS  Yes  “ 

18.  DSTO  RESEARCH  LIBRARY  THESAURUS 

Respirator  cartridges 

19.  ABSTRACT 

One  of  the  critical  elements  related  to  efficiency  and  safe  use  of  respirator  filter  cartridges  is  their  operational 
life  span.  Predicting  the  life  span  of  a  respirator  cartridge  is  difficult  because  it  is  dependant  on  parameters 
such  as  environmental  temperature,  the  nature  and  concentration  of  the  contaminants  and  the  rate  of 
breathing.  Ideally,  respirator  cartridges  should  include  an  End  of  Service  Life  Indicator  (ESLI)  system  to  warn 
the  wearer  when  it  is  time  to  change  cartridges. 

The  development  of  a  cheap,  reliable,  disposable  ESLI  would  significantly  improve  the  protection  of  military 
units  in  a  chemical  warfare  (CW)  environment.  Currently,  no  ESLI  is  available  on  the  market  that  is  capable  of 
detecting  a  range  of  CW  agents  and  toxic  industrial  chemicals  (TICs)  and  therefore,  the  commercialisation 
potential  of  a  successful  ESLI  is  high.  This  report  reviews  all  prior  art  relating  to  ESLIs  for  respirator  cartridges 
which  will  provide  the  foundation  for  future  development  in  this  area. 


Page  classification:  UNCLASSIFIED